CVE-2017-7903
Description
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
Predictions
Heuristic predictions, AS-IS, for prioritization only.
Mitigations
No mitigations published for this CVE yet.
The vendor-content worker queues fetches as references arrive (check back in a few minutes). Or โ if you've already worked around this in production โ publish your fix to the community-verified tier.
โ Propose a mitigation on Community โ Mitigations published via the community go through AI scoring + 2 human reviewers + 7-day silent objection window before landing here withsource_tier=community-verified.
Application impact
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| rockwellautomation | 1763-l16awa_series_a | {"endIncluding":"16.000"} | |
| rockwellautomation | 1763-l16awa_series_b | {"endIncluding":"16.000"} | |
| rockwellautomation | 1763-l16bbb_series_a | {"endIncluding":"16.000"} | |
| rockwellautomation | 1763-l16bbb_series_b | {"endIncluding":"16.000"} | |
| rockwellautomation | 1763-l16bwa_series_a | {"endIncluding":"16.000"} | |
| rockwellautomation | 1763-l16bwa_series_b | {"endIncluding":"16.000"} | |
| rockwellautomation | 1763-l16dwd_series_a | {"endIncluding":"16.000"} | |
| rockwellautomation | 1763-l16dwd_series_b | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32awa_series_a | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32awa_series_b | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32awaa_series_a | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32awaa_series_b | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32bwa_series_a | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32bwa_series_b | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32bwaa_series_a | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32bwaa_series_b | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32bxb_series_a | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32bxb_series_b | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32bxba_series_a | {"endIncluding":"16.000"} | |
| rockwellautomation | 1766-l32bxba_series_b | {"endIncluding":"16.000"} | |
References
CWEs
CWE-521 CWE-326
Community-verified mitigations for this CVE will appear above when contributors publish them.
Verify integrity in audit chain (admin only). AS-IS.