CVE-2022-0715

critical
Published 2022-03-09 ยท Modified 2026-05-29
CVSS v3
9.1
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
CVSS v4 NEW
โ€”
not yet in upstream
VIR risk
9.1

Description

A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Predictions

Exploit likelihood
94%
Patch ETA
โ€”

Heuristic predictions, AS-IS, for prioritization only.

Mitigations

No mitigations published for this CVE yet.

The vendor-content worker queues fetches as references arrive (check back in a few minutes). Or โ€” if you've already worked around this in production โ€” publish your fix to the community-verified tier.

โœš Propose a mitigation on Community โ†’ Mitigations published via the community go through AI scoring + 2 human reviewers + 7-day silent objection window before landing here with source_tier=community-verified.

Application impact

VendorProductVersionsFixed
schneider-electricsmt_series_1015_ups-
schneider-electricsmc_series_1018_ups-
schneider-electricsmtl_series_1026_ups-
schneider-electricscl_series_1029_ups-
schneider-electricscl_series_1030_ups-
schneider-electricscl_series_1036_ups-
schneider-electricscl_series_1037_ups-
schneider-electricsmx_series_1031_ups-
schneider-electricsmt_series_18_ups-
schneider-electricsmt_series_1040_ups-
schneider-electricsmt_series_1031_ups-
schneider-electricsmc_series_1005_ups-
schneider-electricsmc_series_1007_ups-
schneider-electricsmc_series_1041_ups-
schneider-electricsmx_series_20_ups-
schneider-electricsmx_series_23_ups-
schneider-electricsrt_series_1010_ups-
schneider-electricsrt_series_1019_ups-
schneider-electricsrt_series_1025_ups-
schneider-electricsrt_series_1020_ups-
schneider-electricsrt_series_1021_ups-
schneider-electricsrt_series_1001_ups-
schneider-electricsrt_series_1013_ups-
schneider-electricsrt_series_1002_ups-
schneider-electricsrt_series_1014_ups-
schneider-electricsrtl1000rmxli-
schneider-electricsrtl1000rmxli-nc-
schneider-electricsrtl1500rmxli-nc-
schneider-electricsrtl1500rmxli-
schneider-electricsrtl2200rmxli-
schneider-electricsrtl2200rmxli-nc-
schneider-electricsrtl3000rmxli-nc-
schneider-electricsrtl3000rmxli-

References

CWEs

CWE-287 CWE-345

Community-verified mitigations for this CVE will appear above when contributors publish them.

Verify integrity in audit chain (admin only). AS-IS.